# ICS Advisory (ICSA-20-098-05)
## KUKA.Sim Pro
Original release date: April 07, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-098-05)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-098-05)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-098-05)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 4.3**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** KUKA
* **Equipment:** Sim Pro
* **Vulnerability:** Improper Enforcement of Message Integrity During Transmission in a Communication Channel
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability could result in a loss of
integrity in external 3D models fetched from remote servers. When tested on
real machines, this effect is unpredictable.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
KUKA.Sim Pro Version 3.1 simulation and machine-programming software is
affected by this vulnerability.
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [IMPROPER ENFORCEMENT OF MESSAGE INTEGRITY DURING TRANSMISSION IN A
COMMUNICATION CHANNEL
(CWE-924)](https://cwe.mitre.org/data/definitions/924.html)
Simulation models for these devices are hosted by a server maintained by KUKA.
When these devices request a model, the server transmits the model in
plaintext.
[CVE-2020-10635](https://cve.mitre.org/cgi-
bin/cvename.cgi?name=CVE-2020-10635) has been assigned to this vulnerability.
A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Manufacturing
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 3.4 RESEARCHER
Federico Maggi of Trend Micro reported this vulnerability to CISA.
## 4\. MITIGATIONS
KUKA recommends upgrading KUKA.Sim Pro to [Version
3.1.2](https://www.kuka.com/) or above to mitigate this vulnerability. The
update is provided for users with a licensed Version 3.1. Version 3.1 is the
only affected version that is still maintained. All previous versions of
KUKA.Sim Pro have been discontinued; Version 3.0 has been discontinued since
the beginning of 2019.
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target this vulnerability.