# ICS Advisory (ICSA-20-042-05)
## Siemens SIMATIC S7 (Update B)
Original release date: April 14, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-042-05)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-042-05)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-042-05)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 5.3**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** SIMATIC S7
* **Vulnerability:** Uncontrolled Resource Consumption (Resource Exhaustion)
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update titled
ICSA-20-042-05 Siemens SIMATIC S7 (Update A) that was published March 10,
2020, to the ICS webpage on us-cert.gov.
## 3\. RISK EVALUATION
Successful exploitation of this vulnerability could allow remote attackers to
perform a denial-of-service attack by sending a specially crafted HTTP request
to the web server of an affected device.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
The following versions of SIMATIC S7 devices are affected:
* SIMATIC S7-1200 CPU family (incl. SIPLUS variants) all versions prior to v4.1
* SIMATIC S7-300 PN/DP CPU family (incl. related ET200 CPUs and SIPLUS variants) all versions prior to V3.x.17
* SIMATIC S7-400 PN/DP v6 and below CPU family (incl. SIPLUS variants) all versions
* SIMATIC S7-400 PN/DP v7 CPU family (incl. SIPLUS variants) all versions
**\--------- Begin Update B Part 1 of 1 ---------**
* SIMATIC WinAC (F) 2010 all versions
**\--------- End Update B Part 1 of 1 ---------**
### 4.2 VULNERABILITY OVERVIEW
#### 4.2.1 [UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION')
CWE-400](https://cwe.mitre.org/data/definitions/400.html)
Affected devices contain a vulnerability that could cause a denial-of-service
condition of the web server by sending specially crafted HTTP requests to
Ports 80/TCP and 443/TCP.
[CVE-2019-13940](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13940)
has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been
assigned; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L)).
### 4.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 4.4 RESEARCHER
China Industrial Control Systems Cyber Emergency Response Team (CIC) reported
this vulnerability to Siemens.
## 5\. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations
users can apply to reduce the risk:
* Restrict access to the device to the internal or VPN network. Further, if possible, restrict access to the web server (80/TCP, 443/TCP) to trusted IP addresses.
* If possible, disable the integrated web server. The web server is disabled in the default settings and its use is optional.
* For SIMATIC S7-1200 CPU family (including SIPLUS variants) Siemens recommends affected users [update to v4.1](https://support.industry.siemens.com/cs/ww/en/view/109763919) or any later version.
* For SIMATIC S7-300 PN/DP CPU family (including related ET200 CPUs and SIPLUS variants), Siemens recommends affected users [update to v3.X.17](https://support.industry.siemens.com/cs/ww/en/view/109778547) or later version.
For more information on this vulnerability and associated software updates,
please see Siemens security advisory
[SSA-431678](https://www.siemens.com/cert/advisories)
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target this vulnerability.