# ICS Advisory (ICSA-18-347-03)
## Geutebruck GmbH E2 Series IP Cameras
Original release date: December 13, 2018
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-347-03)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-347-03)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-347-03)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.2**
* **ATTENTION** : Exploitable remotely/low skill level to exploit
* **Vendor** : Geutebruck GmbH
* **Equipment** : E2 Camera Series
* **Vulnerability** : OS Command Injection
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability may allow a remote attacker to
inject OS commands as root.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
Geutebruck reports the vulnerability affect the following IP cameras:
E2 series cameras running firmware versions prior to 1.12.0.25
### 3.2 VULNERABILITY OVERVIEW
**3.2.1 [IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND
('OS COMMAND INJECTION')
CWE-78](https://cwe.mitre.org/data/definitions/78.html)**
The DDNS configuration (in the Network Configuration panel) is vulnerable to
an OS system command injection as root.
[CVE-2018-19007](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19007)
has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS** : Commercial Facilities, Energy, Financial Services, Healthcare and Public Health
* **COUNTRIES/AREAS DEPLOYED** : Europe, United States, Australia
* **COMPANY HEADQUARTERS LOCATION** : Germany
### 3.4 RESEARCHER
Davy Douhine of RandoriSec reported this vulnerability to NCCIC. The
researcher has validated that the new version of the firmware resolves the
reported vulnerability.
## 4\. MITIGATIONS
Geutebruck recommends E2 series IP camera users download and update to the
newest firmware version, 1.12.0.25, by registering for a new WebClub account,
or by logging into an existing account at the following location:
<https://www.geutebrueck.com//en_EN/login.html>
NCCIC recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
NCCIC reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
NCCIC also provides a section for [control systems security recommended
practices](/ics/content/recommended-practices) on the ICS-CERT web page.
Several recommended practices are available for reading and download,
including [Improving Industrial Control Systems Cybersecurity with Defense-in-
Depth Strategies](/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS-CERT website](/ics/) in the Technical Information Paper,
[ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation
Strategies](/ics/tips/ICS-TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to NCCIC for
tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.
暂无评论