# ICS Advisory (ICSA-19-281-04)
## Siemens SIMATIC IT UADM
Original release date: October 08, 2019
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-281-04)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-281-04)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-281-04)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 6.8**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** SIMATIC IT Unified Architecture Discrete Manufacturing (UADM)
* **Vulnerability:** Use of Hard-coded Cryptographic Key
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to gain
read and write access to the related TeamCenter station.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
The following versions of Siemens SIMATIC IT UADM, a part of the SIMATIC IT
manufacturing execution system, are affected:
* SIMATIC IT UADM: All versions prior to 1.3
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [USE OF HARD-CODED CRYPTOGRAPHIC KEY
CWE-321](https://cwe.mitre.org/data/definitions/321.html)
An authenticated remote attacker could recover a password over Port 1434/TCP,
which may be used to gain read/write access to the related TeamCenter station.
[CVE-2019-13929](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13929)
has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been
assigned; the CVSS vector string is
([AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Critical Manufacturing
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 3.4 RESEARCHER
Siemens reported this vulnerability to CISA.
## 4\. MITIGATIONS
Siemens recommends users update to Version 1.3, which can be obtained from a
Siemens account manager.
Siemens has identified the following specific workarounds and mitigations
users can apply to reduce the risk:
* Protect network access to Port 1434/TCP of machines running SIMATIC IT UADM software.
* Apply cell protection concept and implement defense-in-depth.
As a general security measure, Siemens strongly recommends protecting network
access to devices with appropriate mechanisms. In order to operate the devices
in a protected IT environment, Siemens recommends configuring the environment
according to Siemens' [operational guidelines for Industrial
Security](https://www.siemens.com/cert/operational-guidelines-industrial-
security), and following the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>
For more information on this vulnerability and more detailed mitigation
instructions, please see Siemens security advisory SSA-984700 at the following
location: <http://www.siemens.com/cert/advisories>
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target this vulnerability.
暂无评论