# ICS Advisory (ICSA-19-344-03)
## Siemens RUGGEDCOM ROS
Original release date: December 10, 2019
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-03)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-03)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-03)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.8**
* **ATTENTION:** Low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** RUGGEDCOM ROS
* **Vulnerabilities:** Improper Restriction of Operations within the Bounds of a Memory Buffer, Resource Management Errors
## 2\. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow a denial-of-
service condition or arbitrary code execution.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
The following versions of RUGGEDCOM ROS, an ethernet switch, are affected:
* RMC8388: all versions
* RSG2488: all versions
* RSG920P: all versions
* RSG9xx R/C: all versions
* RSL910: all versions
* RST2228: all versions
Some of these devices are only affected by one of these vulnerabilities,
please see SSA-618620 for details.
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY
BUFFER CWE-119](https://cwe.mitre.org/data/definitions/119.html)
The embedded boot loader has a locally exploitable buffer overflow via a
crafted kernel image because the filesystem loading is mishandled.
[CVE-2018-18440](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-18440)
has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been
calculated; the CVSS vector string is
([AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)).
#### 3.2.2 [RESOURCE MANAGEMENT ERRORS
CWE-399](https://cwe.mitre.org/data/definitions/399.html)
The embedded boot loader has a physically exploitable vulnerability. A crafted
self-referential DOS partition table will cause the bootloader to infinitely
recurse, causing the stack to grow infinitely and eventually crash.
[CVE-2019-13103](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13103)
has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been
calculated; the CVSS vector string is
([AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Energy, Healthcare and Public Health, Transportation Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 3.4 RESEARCHER
Siemens reported these vulnerabilities to CISA.
## 4\. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations
users can apply to reduce risk:
* CVE-2018-18440: Disable boot interface access during boot up via the 'bootoption.txt' file parameter 'Security = yes'.
* CVE-2019-13103: Disable access to the removable media via 'bootoption.txt' file parameter 'Disableautoaccessremovable = yes'. Note that this vulnerability only applies to RUGGEDCOM ROS, if the device boots from removable media.
As a general security measure, Siemens strongly recommends protecting network
access to devices with appropriate mechanisms. In order to operate the devices
in a protected IT environment, Siemens recommends configuring the environment
according to Siemens' operational guidelines for industrial security and
following the recommendations in the product manuals.
Additional information on industrial security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>
For more information on this vulnerability and more detailed mitigation
instructions, please see Siemens security advisory SSA-618620 at the following
location:
<http://www.siemens.com/cert/advisories>
CISA recommends users take defensive measures to minimize the risk of
exploitation of these vulnerabilities. Specifically, users should:
* Restrict access to devices following a least privilege principle.
* Implement physical security controls to mitigate unauthorized physical access.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target these vulnerabilities. These
vulnerabilities are not exploitable remotely.