# ICS Advisory (ICSA-19-344-06)
## Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update A)
Original release date: March 10, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-06)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-06)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-344-06)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 5.3**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** SIMATIC S7-1200 and S7-1500 CPU families
* **Vulnerabilities:** Use of a Broken or Risky Cryptographic Algorithm, Missing Support for Integrity Check
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled
ICSA-19-344-06 Siemens SIMATIC S7-1200 and S7-1500 CPU Families that was
published December 10, 2019, on the ICS webpage on us-cert.gov.
## 3\. RISK EVALUATION
Successful exploitation of these vulnerabilities may allow an attacker to
modify network traffic or impact the perceived integrity of the user program
stored on the CPU.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
Siemens reports that these vulnerabilities affect the following SIMATIC
products:
* SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC: All versions
**\--------- Begin Update A Part 1 of 2 ---------**
* SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC2: Versions 20.8 and prior
* SIMATIC S7-1500 Software Controller: Versions 20.8 and prior
**\--------- End Update A Part 1 of 2 ---------**
* SIMATIC S7 PLCSIM Advanced: Versions 3.0 and prior
* SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Versions 4.4 and prior
* SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518-4 PN/DP and CPU 1518 MFP (and related SIPLUS variant): All versions up to and including v2.8.1
### 4.2 VULNERABILITY OVERVIEW
#### 4.2.1 [USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM
CWE-327](https://cwe.mitre.org/data/definitions/327.html)
An attacker in a man-in-the-middle position could modify network traffic
exchanged on Port 102/TCP, due to certain properties in the calculation used
for integrity protection.
[CVE-2019-10929](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10929)
has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been
calculated; the CVSS vector string is
([AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N)).
#### 4.2.2 [MISSING SUPPORT FOR INTEGRITY CHECK
CWE-353](https://cwe.mitre.org/data/definitions/353.html)
An attacker with network access to Port 102/TCP could modify the user program
on the PLC in a way that the running code is different from the source code
stored on the device.
[CVE-2019-10943](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10943)
has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N)).
### 4.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 4.4 RESEARCHER
Eli Biham, Sara Bitan, Aviad Carmel, and Alon Dankner from Faculty of Computer
Science, Technion Haifa; Uriel Malin and Avishai Wool from School of
Electrical Engineering, Tel-Aviv University; and Artem Zinenko from Kaspersky
reported these vulnerabilities to Siemens.
## 5\. MITIGATIONS
Siemens has released updates for the following products and recommends users
update to the new version.
* SIMATIC S7 PLCSIM Advanced: [Update to v3.0](https://support.industry.siemens.com/cs/document/109772889/)
* SIMATIC S7-1200 CPU family: [Update to v4.4](https://support.industry.siemens.com/cs/search?search=S7-1200%20V4.4%20&type=Download)
* SIMATIC S7-1500 CPU family: [Update to v2.8.1](https://support.industry.siemens.com/cs/document/109478459/)
**\--------- Begin Update A Part 2 of 2 ---------**
* SIMATIC ET 200SP Open Controller CPU 1515SP PC2: [Update to v20.8](https://support.industry.siemens.com/cs/document/109759122/)
* SIMATIC S7-1500 Software Controller: [Update to v20.8](https://support.industry.siemens.com/cs/document/109759122/)
**\--------- End Update A Part 2 of 2 ---------**
Siemens is preparing further updates and recommends specific countermeasures
until patches are available:
* All affected devices contain a feature called "Access Protection" that prohibits unauthorized modifications of user code. Siemens recommends using access protection to protect affected devices from unauthorized modifications.
As a general security measure, Siemens strongly recommends users protect
network access to devices with appropriate mechanisms. In order to operate the
devices in a protected IT environment, Siemens recommends users configure the
environment according to Siemens' [operational guidelines for industrial
security](https://www.siemens.com/cert/operational-guidelines-industrial-
security), and follow the recommendations in the product manuals. Additional
information on industrial security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>.
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.
暂无评论