# ICS Advisory (ICSA-20-072-02)
## ABB Asset Suite
Original release date: March 12, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-072-02)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-072-02)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-072-02)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.1**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** ABB
* **Equipment:** Asset Suite
* **Vulnerability:** Authorization Bypass Through User-Controlled Key
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker access
to unauthorized information in the application by direct resource access.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
The following versions of Asset Suite are affected:
* Asset Suite Versions 9.6 and prior, excluding 9.4.2.6 and 9.5.3.2
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [AUTHORIZATION BYPASS THROUGH USER-CONTROLLED KEY
CWE-639](https://cwe.mitre.org/data/definitions/639.html)
There is a flaw in the access controls used to limit user access to resources.
If an attacker knows, or were to discover, the URL for a resource they do not
have permissions to, they would be able to access the resource by browsing
directly to the URL.
[CVE-2019-18998](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-18998)
has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been
assigned; the CVSS vector string is
([AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Energy
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Switzerland
### 3.4 RESEARCHER
ABB reported this vulnerability to CISA.
## 4\. MITIGATIONS
ABB recommends users apply the update as soon as they are able. The following
updates mitigate this vulnerability:
* Versions 9.4.2.6, 9.5.3.2, and 9.6.1
For additional information and support, please contact your local ABB service
organization. For contact information, see <https://new.abb.com/contact-
centers> or visit <http://www.abb.com/cybersecurity>
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target this vulnerability.