# ICS Advisory (ICSA-19-227-04)
## Siemens SINAMICS (Update C)
Original release date: May 12, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-227-04)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-227-04)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-227-04)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.5**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** SINAMICS
* **Vulnerability:** Uncontrolled Resource Consumption
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update ICSA-19-227-04
Siemens SINAMICS (Update B) that was published December 10, 2019, to the ICS
webpage on us-cert.gov.
## 3\. RISK EVALUATION
Successful exploitation of this vulnerability may allow an attacker to perform
a denial-of-service attack.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
Siemens reports the vulnerability affects webservers of the following
industrial products:
* SINAMICS GH150 v4.7 (Control Unit): All versions
* SINAMICS GH150 v4.8 (Control Unit): All versions prior to v4.8 SP2 HF6
* SINAMICS GL150 v4.7 (Control Unit): All versions
* SINAMICS GL150 v4.8 (Control Unit): All versions prior to v4.8 SP2 HF7
* SINAMICS GM150 v4.7 (Control Unit): All versions
* SINAMICS GM150 v4.8 (Control Unit): All versions prior to v4.8 SP2 HF9
* SINAMICS SL150 v4.7 (Control Unit): All versions prior to v4.7 HF33
**\--------- Begin Update C Part 1 of 2 ---------**
* SINAMICS SL150 v4.8 (Control Unit): All versions prior to v5.2 SP2
**\--------- End Update C Part 1 of 2 ---------**
* SINAMICS SM120 v4.7 (Control Unit): All versions prior to v4.8 SP2 HF10SINAMICS SM120 v4.8 (Control Unit): All versions prior to v4.8 SP2 HF10
* SINAMICS SM150 v4.8 (Control Unit): All versions
### 4.2 VULNERABILITY OVERVIEW
#### 4.2.1 [UNCONTROLLED RESOURCE CONSUMPTION
CWE-400](https://cwe.mitre.org/data/definitions/400.html)
The webserver of the affected devices contains a vulnerability that may lead
to a denial-of-service condition. An attacker may cause a denial-of-service
situation, leading to a restart of the webserver of the affected device. The
security vulnerability could be exploited by an attacker with network access
to the affected systems. Successful exploitation requires no system privileges
and no user interaction.
[CVE-2019-6568](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6568)
has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)).
### 4.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Chemical, Commercial Facilities, Critical Manufacturing, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 4.4 RESEARCHER
Siemens reported this vulnerability to CISA.
## 5\. MITIGATIONS
Siemens currently recommends the following updates for the following products:
SINAMICS GH150 v4.7 (Control Unit), SINAMICS GH150 v4.8 (Control Unit,
SINAMICS GL150 v4.7 (Control Unit), SINAMICS GL150 v4.8 (Control Unit),
SINAMICS GM150 v4.7 (Control Unit), and SINAMICS GM150 v4.8 (Control Unit)
* Update to v4.8 SP2 HF9
SINAMICS SL150 v4.7 (Control Unit)
* Update to v4.7 HF33
**\--------- Begin Update C Part 2 of 2 ---------**
SINAMICS SL150 v4.8 (Control Unit)
* Update to v 5.2 SP2
**\--------- End Update C Part 2 of 2 ---------**
SINAMICS SM120 v4.7 and v4.8 (Control Unit)
* Update to v4.8 SP2 HF10
SINAMICS SM150 v4.8 (Control Unit)
* Upgrade to v5.1 SP2 HF3
The update can be obtained from a Siemens representative or via Siemens
customer service.
Siemens has identified the following specific workarounds and mitigations
users can apply to reduce the risk:
* Restrict network access to the integrated webserver.
* Deactivate the webserver if not required, and if deactivation is supported by the product. For SINAMICS products, webserver may be deactivated with parameter P8986 = 0
As a general security measure, Siemens strongly recommends users protect
network access to devices with appropriate mechanisms. In order to operate the
devices in a protected IT environment, Siemens recommends users configure the
environment according to [Siemens' operational guidelines for industrial
security](https://assets.new.siemens.com/siemens/assets/public.1502968141.411e91564a2d259ecd4b6c79b51f89c044b3de81.operational-
guidelines-industrial-security-en.pdf), and follow the recommendations in the
product manuals. Additional information on industrial security by Siemens can
be found at: <https://www.siemens.com/industrialsecurity>
For more information on the vulnerability and more detailed mitigation
instructions, please see Siemens Security Advisory
[SSA-530931](http://www.siemens.com/cert/advisories)
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target this vulnerability.