# ICS Advisory (ICSA-20-219-03)
## Geutebruck G-Cam and G-Code
Original release date: August 06, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-219-03)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-219-03)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-219-03)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.2**
* **ATTENTION:** Exploitable remotely/low skill level to exploit/public exploits are available
* **Vendor:** Geutebruck
* **Equipment:** G-Cam and G-Code
* **Vulnerability:** OS Command Injection
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability could allow remote code
execution as root.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
Geutebruck reports the vulnerability affects firmware Versions 1.12.0.25 and
prior as well as the limited Versions 1.12.13.2 and 1.12.14.5 of the following
Encoder and E2 Series Camera models:
* G-Code:
* EEC-2xxx
* G-Cam:
* EBC-21xx
* EFD-22xx
* ETHC-22xx
* EWPC-22xx
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND
('OS COMMAND INJECTION')
CWE-78](https://cwe.mitre.org/data/definitions/78.html)
Using a specially crafted URL command, a remote authenticated user can execute
commands as root.
[CVE-2020-16205](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-16205)
has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Commercial Facilities, Energy, Financial Services, Government Facilities, Healthcare and Public Health, Transportation Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 3.4 RESEARCHER
Davy Douhine of RandoriSec reported this vulnerability to CISA.
## 4\. MITIGATIONS
Geutebruck recommends users update to firmware Version 1.12.0.27
The link for the download area on the Geutebruck website "[latest
firmware](https://portal.geutebrueck.com/)" is the same as for the advisory
"[security advisory](https://portal.geutebrueck.com/)" (Login required).
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
CISA recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
暂无评论