# ICS Advisory (ICSA-20-196-05)
## Siemens UMC Stack (Update B)
Original release date: September 08, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-196-05)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-196-05)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-20-196-05)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 6.7**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** UMC Stack
* **Vulnerabilities:** Unquoted Search Path or Element, Uncontrolled Resource Consumption, Improper Input Validation
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update titled
ICSA-20-196-05 Siemens UMC Stack (Update A) that was published August 11,
2020, to the ICS webpage on us-cert.gov.
## 3\. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to
cause a partial denial-of-service condition on the UMC component of the
affected devices under certain circumstances. This could also allow an
attacker to locally escalate privileges from a user with administrative
privileges to execute code with SYSTEM level privileges.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
Siemens reports that some of the vulnerabilities affect the following UMC
components. For a complete list of which specific vulnerabilities affect each
of these products, please see Siemens security advisory
[SSA-841348](https://www.siemens.com/cert/advisories):
* Opcenter Execution Discrete: All versions prior to v3.2
* Opcenter Execution Foundation: All versions prior to v3.2
* Opcenter Execution Process: All versions prior to v3.2
* Opcenter Intelligence: All versions
* Opcenter Quality: All versions prior to v11.3
* Opcenter RD&L: v8.0
* SIMATIC IT LMS: All versions
* SIMATIC IT Production Suite: All versions
* SIMATIC Notifier Server for Windows: All versions
**\--------- Begin Update B Part 1 of 2 ---------**
* SIMATIC STEP 7 (TIA Portal) v15: All versions prior to v15.1 update 5
**\--------- End Update B Part 1 of 2 ---------**
* SIMATIC PCS neo: All versions prior to v3.0 SP1
* SIMATIC STEP 7 (TIA Portal) v16: All versions prior to v16 Update 2
* SIMOCODE ES: All versions
* Soft Starter ES: All versions
### 4.2 VULNERABILITY OVERVIEW
#### 4.2.1 [UNQUOTED SEARCH PATH OR ELEMENT
CWE-428](https://cwe.mitre.org/data/definitions/428.html)
A component within the affected application calls a helper binary with SYSTEM
privileges during startup while the call path is not quoted.
[CVE-2020-7581](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7581)
has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been
calculated; the CVSS vector string is
(A[V:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)).
#### 4.2.2 [UNCONTROLLED RESOURCE CONSUMPTION
CWE-400](https://cwe.mitre.org/data/definitions/400.html)
Sending multiple specially crafted packets to the affected service could cause
a partially remote denial of service, which would cause the service to restart
itself.
[CVE-2020-7587](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7587)
has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L)).
#### 4.2.3 [IMPROPER INPUT VALIDATION
CWE-20](https://cwe.mitre.org/data/definitions/20.html)
Sending a specially crafted packet to the affected service could cause a
partially remote denial of service, which would cause the service to restart
itself.
[CVE-2020-7588](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7588)
has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L)).
### 4.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Critical Manufacturing
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 4.4 RESEARCHER
Victor Fidalgo of INCIBE and Reid Wightman of Dragos reported these
vulnerabilities to Siemens.
## 5\. MITIGATIONS
Siemens recommends users upgrade affected products if upgrade are available
for those products:
* Opcenter Execution Discrete, Foundation, and Process: [Update to v3.2 or later](https://support.sw.siemens.com/)
* Opcenter Quality: [Update to v11.3 or later](https://support.sw.siemens.com/)
* Opcenter RD&L: [Update to v8.1 or later](https://support.sw.siemens.com/)
* SIMATIC PCS neo: Update to v3.0 SP1. To obtain this update contact local support.
**\--------- Begin Update B Part 2 of 2 ---------**
* SIMATIC STEP 7 (TIA Portal) v15: [Update to v15.1 update 5 or later](https://support.industry.siemens.com/cs/ww/en/view/109775861)
**\--------- End Update B Part 2 of 2 ---------**
* SIMATIC STEP 7 (TIA Portal) v16: [Update to v16 Update 2 or later](https://support.industry.siemens.com/cs/ww/en/view/109775861)
For products that do not have an update, Siemens has identified the following
specific workarounds and mitigations customers can apply to reduce the risk:
* Run the software on systems within trusted networks
* For CVE-2020-7581, ensure there is no executable at the following locations:
* C:\Program.exe
* C:\Program Files\Common.exe
* C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
As a general security measure, Siemens strongly recommends protecting network
access to devices with appropriate mechanisms. To operate the devices in a
protected IT environment, Siemens recommends configuring the environment
according to [Siemens' operational guidelines for Industrial
Security](https://www.siemens.com/cert/operational-guidelines-industrial-
security) and following the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>
For more information on these vulnerabilities and associated software updates,
please see Siemens security advisory
[SSA-841348](https://www.siemens.com/cert/advisories)
CISA recommends users take the following measures to protect themselves from
social engineering attacks:
* Do not click web links or open unsolicited attachments in email messages.
* Refer to [Recognizing and Avoiding Email Scams](https://www.us-cert.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams.
* Refer to [Avoiding Social Engineering and Phishing Attacks](https://www.us-cert.gov/ncas/tips/ST04-014) for more information on social engineering attacks.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.